Caracteristicas:
Sample Flow Rate 50 mL/minute ±10 mL/minute
Principle of Operation Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
Initialization Time Capnogram, displayed in less than 20 seconds, at an ambient temperature of 25°C, full specifications within 2 minutes
CO2Measurement Range 0 to 150 mmHg, 0 to 19.7%, 0 to 20 kPa
CO2 Resolution
0.1 mmHg 0 to 69 mmHg
0.25 mmHg 70 to 150 mmHg
CO2 Accuracy
0 – 40 mmHg ±2 mmHg
41 – 70 mmHg ±5% of reading
71 – 100 mmHg ±8% of reading
101 – 150 mmHg ±10% of reading
Above 80 BPM ±12% of reading
CO2 Stability Short term drift: Drift over four hours shall not exceed 0.8 mmHg maximum
Long term drift: Accuracy specification will be maintained over a 120-hour period
CO2 Noise RMS noise of the sensor is less than or equal to 0.25 mmHg at 5% CO2
Sampling Frequency 100 Hz
Respiration Rate Range 0 to 150 Breaths Per Minute (BPM)
Respiration Rate Accuracy ±1 breath
Compensations (Supplied by Host) Barometric pressure: 400 mmHg to 800 mmHg
Operator selectable O2, N2O, HE and agent compensation
Calibration No routine user calibration required
Sample Cell/Filter Proprietary single patient use sample cell and inline filter are integrated with the sample line which effectively eliminates contamination of the internal system
Nasal Sampling Kits for Non-intubated Patients Nasal CO2 or CO2 with O2 delivery (Adult,Pediatric,Infant-Neonatal)
Nasal/Oral CO2 or CO2 with O2 delivery (Adult, Pediatric)
Airway Adapter Kits for Intubated Patients Adult/Pediatric with and without dehumidification tubing
Pediatric/Infant, low deadspace, with and without dehumidification tubing
Taper meets ISO 5356-1
Sample Kit Hours of Use Nasal and Oral/Nasal Cannulas without nafion – up to 12 hours
Nasal and Oral/Nasal Cannulas with nafion – up to 120 hours
Airway Adapter Kits without nafion - up to 12 hours
Airway Adapter Kits with nafion - up to 120 hours
Sample Cell Detection Insertion automatically turns sampling pump on. Removal automatically turns sampling pump off
Flow Control Via ΔP measurement across a capillary tube
Scavenging Port Yes
Voltage Requirements 5.0 VDC ±5%
Power Rating Rated input: Less than 1.3 Watts typical
Steady state less than 2.0 Watts maximum on power up (warm up)
Interconnection Standard - Lemo Redel 8-pin plastic
LoFlo and CAPNOSTAT are interchangeable with the host monitor Common connector allows easy exchange between mainstream and sidestream monitoring
Temperature and Humidity Operating: 0° to 40°C, 10 to 90% RH, non-condensing
Storage: -40° to 70°C,